The XALT Energy Advantage
- Exceptional cycle life with proven XALT NMC SHE cells
- High specific energy and volumetric energy density
- Rugged design for challenging environments
- Outstanding safety and abuse tolerance
- Efficient direct liquid cooling maintains ideal cell temperatures
- IP67 compliant (with connectors mated)
- Easy to install, configure and upgrade
- ISO 9001:2015 certified production environment
Modular and Flexible Design
- Easy to customize high voltage, low voltage and cooling interfaces to each application
- All connections at front panel; rear access not needed for installation
System Support
- Battery Disconnect Unit (BDU)
- Master Control Unit (MCU)
- Low Voltage Harness (LVH) Kit
- High Voltage Cable (HVC) Sets
- XALT Battery Viewer (XBV) Telematics
- XALT Rack System (XRS)
Lifecycle Support
- XPAND Service Tool
- Remote Data Monitoring & Prognostics
- Pack Replacement Maintaining Interface Connections
- End-of-Life Re-purposing, Recycling
- Integration Support
- On-site Training Classes
Performance* | |
---|---|
Nominal Capacity (Rated @ C/10) | 138 Ah |
Discharge Energy (Rated @ C/10) | 12.3 kWh |
Nominal Voltage | 88.6 V |
Specific Power* | ≥ 259 W/kg |
Specific Energy | ≥ 160 Wh/kg |
Specific Density | ≥ 188 Wh/l |
Discharge Peak* | 2.0C / 284 A |
Charge Peak* | 0.5C / 71 A |
Discharge Continuous** | 1.0C / 142 A |
Charge Continuous** | 0.4C / 56.8 A |
Weight | 76.7 kg |
Dimension (all versions incl. base) | (L) 753 mm (W) 303 mm (H) 282 mm |
*10 seconds duration
**Cell performance will be affected by temperature, SoC, SoH, aging, etc.
Cycle Life | |||
---|---|---|---|
100% DOD Cycles @ 0.3C charge-discharge | > 3,000 cycles*** | ||
80% DOD Cycles @ 0.3C charge-discharge | > 4,000 cycles*** |
***Cycle life to 80% of rated capacity at 25°C room temperature with 10 min. step rest